Catalogue
Power supply organizer TWIST PO12-2 is designed to supply a stabilized 12V voltage cameras and other equipment, as well as the circuits protection of overloaded voltage. It can be used for remote power supply for video cameras in the multi-power circuit security television systems.
![]()
Operating conditions
| Operating Temperature Range | -40 to +55°С |
| Relative humidity | 0 to 100% |
| Input voltage, current up to 2 A | 15–36 V DC/AC |
| The number of simultaneously connected loads | 1-5 |
| Stabilized output voltage | 12 V +/-3% |
| The output voltage pulses in the range 20MGts | up to 30 mV (between peaks) |
| Total output load current (all channels) | up to 2 A |
| Maximum power consumption | 35 W |
| Protection availability | |
| - incorrect input polarity | yes |
| - overheating | yes |
| - input overvoltage | yes |
| - output overcurrent | yes |
| - output overvoltage | yes |
| Dimensions | 142х102х56 mm |
| Warranty period | 36 months |
The device comes as the outdoor case IP-66.
- Before switching on, connect the input and output cables according to the label on the lid of the device and tight the hermetic input nuts. For the sealing of the case do not leave unused hermetic inputs without cable (you can insert small pieces of the cable and tight the hermetic input nuts).
- Make sure that the parameters of the input voltage and total current consumption of pluged loads (cameras) are consistent with those in the specification.
- Supply power to the device and determine its status in the table below.
| LED is on | Mode | Output voltage | Reason | Action |
No light |
Unknown | 0 V | 1. The device is not connected 2. Input overload, F1 is out of service |
1. Check the connection of input and fuse F1 2. Replace F1 |
Green |
Normal | 12 V | ||
Yellow or (Green + Yellow) |
Stabilization collapse | Below normal values | Low input voltage of the connected load | Increase the input voltage or reduce the current consumption of the load |
Red + (Green or Yellow) |
Fuse F2 is broken | Unknown | Output overload | Replace fuse F2 |